Furnace Fault Codes
What your furnace's blinking light or error code actually means
Most furnaces report faults by flashing a status LED a set number of times, or by showing a code on a small display. Each entry below explains what a given signal means, what normally causes it, what you can safely check yourself, and when it needs a licensed technician.
Goodman and Amana
- 1 flash — Lockout after too many failed ignition attempts
- 2 flashes — Pressure switch is closed when it should be open
- 3 flashes — Pressure switch will not close
- 4 flashes — High limit switch is open — the furnace is overheating
- 5 flashes — Flame detected when no flame should be present
- 6 flashes — Rollout switch has tripped
- 7 flashes — Flame signal is too weak
- 8 flashes — Igniter circuit fault, most often caused by poor grounding
- 9 flashes — High stage pressure switch stuck open
- rapid flashing — Reversed 115 volt polarity, a grounding problem, or an open igniter circuit
- LED off — No power to the furnace, or an internal control fault
- continuous on — Normal operation — no fault stored
- 6 flashes — Rollout limit open, or control module fuse blown
Goodman and Amana display codes
- E0 — Lockout after too many failed ignition attempts
- E1 — Low stage pressure switch closed at the start of the heating cycle
- E2 — Low stage pressure switch stuck open
- E3 — High limit switch is open — the furnace is overheating
- E4 — Flame detected when no flame should be present
- E5 — Low voltage fuse is open
- E6 — Flame signal is too weak
- E7 — Igniter fault or improper grounding
- E8 — High stage pressure switch closed at the start of the heating cycle
- E9 — High stage pressure switch stuck open
- EA — Reversed 115 volt polarity
- Ed — Rollout switch has tripped
- EC — Inducer motor overcurrent
- EF — Auxiliary switch or input is open
Goodman and Amana blower codes
- b0 — Blower motor is not running
- b1 — Blower communication error
- b2 — Blower motor horsepower mismatch
- b3 — Blower motor operating at a power, temperature, or speed limit
- b4 — Blower motor current trip or lost rotor
- b5 — Blower motor locked rotor
- b6 — Blower motor over or under voltage trip, or over temperature trip
- b7 — Incomplete parameters sent to the motor
- b9 — Low indoor airflow
- d0 — Data not yet on network
- d4 — Invalid memory card data
Carrier and Bryant
- Status code 11 — No previous code stored
- Status code 12 — Blower running after power up
- Status code 13 — Limit circuit lockout
- Status code 14 — Ignition lockout
- Status code 21 — Gas heating lockout — will not reset automatically
- Status code 22 — Abnormal flame-proving signal — flame detected with the gas valve closed
- Status code 23 — Pressure switch did not open
- Status code 24 — Secondary voltage fuse is open
- Status code 31 — Pressure switch did not close, or reopened
- Status code 33 — Limit circuit fault — a limit or flame rollout switch is open
- Status code 34 — Ignition proving failure
- Status code 45 — Control circuitry lockout
- LED continuously off — No power reaching the control
- LED rapid flashing — Line voltage polarity reversed
- Status code retrieval, amber LED controls — How to read stored status codes on Carrier amber LED boards
Trane and American Standard
- 2 flashes — System lockout — retries or recycles exceeded
- 3 flashes — Draft pressure error
- 4 flashes — Open high limit device
- 5 flashes — Flame sensed when no flame should be present
- 6 flashes — 115 volt AC power reversed, or poor grounding
- 7 flashes — Gas valve circuit error
- 8 flashes — Low flame sense signal
- 9 flashes — Ignitor circuit problem, or low voltage between neutral and 24 volt common
- Flashing slow — Normal — no call for heat
- Flashing fast — Normal — call for heat
- Continuous on — Replace the integrated furnace control
- Continuous off — Check power
Rheem, Ruud and Weather King
- 1 blink — Soft lockout, one hour
- 2 blinks — Pressure switch failure — switch remains open
- 3 blinks — Limit switch open
- 4 blinks — Pressure switch failure — switch remains closed
- 5 blinks — Twinning circuit failure
Goodman GMEC96 and Amana AMEC96 colour codes
- 1 red flash — Flame sensed when no flame should be present
- 2 red flashes — Pressure switch stuck closed, or an inducer error
- 3 red flashes — First stage pressure switch stuck open, or an inducer error
- 3 double red flashes — Second stage pressure switch stuck open, or an inducer error
- 4 red flashes — Open limit switch
- 5 red flashes — Open rollout switch, or open fuse detected
- 6 red flashes — Pressure switch cycle lockout
- 7 red flashes — External lockout — ignition retries exhausted
- 8 red flashes — External lockout — recycles exhausted
- 9 red flashes — Grounding problem or reversed polarity
- 10 red flashes — Gas flow detected with a call for heat
- 11 red flashes — Limit switch open due to blower failure
- 12 red flashes — Ignitor relay failure
- rapid amber flashing — Low flame sense current
- rapid red flashing — Twinning error
- solid red — Internal control fault, gas valve error, microprocessor or frequency check failure
- 3 amber flashes — Second stage heat called with no first stage call
- 4 amber flashes — Cooling called with no fan call
- 1 amber flash — Normal operation — first stage heat
- solid green — Standby — powered, no call
Lennox communicating alert codes
- Alert code 200 — Rollout limit switch open
- Alert code 204 — Check gas valve
- Alert code 205 — Gas valve relay contact closed
- Alert code 206 — Gas valve second stage relay fault
- Alert code 207 — Hot surface igniter sensed open
- Alert code 223 — Low pressure switch open
- Alert code 226 — High pressure switch stuck closed
- Alert code 227 — Low pressure switch open in run mode
- Alert code 228 — Inducer calibration issue
- Alert code 229 — Ignition on high fire — information only
- Alert code 240 — Low flame current in run mode
- Alert code 250 — Flame out of sequence — still present
- Alert code 251 — Primary limit switch open
- Alert code 252 — Discharge air temperature high
- Alert code 270 — Flame failed to ignite — Watchguard
- Alert code 271 — Low pressure switch open — Watchguard
- Alert code 272 — Low pressure switch open in run mode — Watchguard
- Alert code 273 — Flame failed in run mode — Watchguard
- Alert code 274 — Primary limit switch open more than three minutes — Watchguard
- Alert code 201 — Indoor blower motor communication lost
- Alert code 202 — Blower motor and unit size mismatch
- Alert code 203 — Invalid or unset unit size code
York, Luxaire and Coleman
- Fault code retrieval — How to read and clear stored fault codes on York UTEC boards
- Green heartbeat — Normal operation, no call for heat, no active errors
- Amber heartbeat — Normal operation with a call for heat
- 1 red flash — Flame sensed with the gas valve off
- 3 red flashes — Pressure switch open, or first stage pressure switch open
- 3 double red flashes — Second stage pressure switch stuck open
- 5 red flashes — Open rollout switch
- 6 red flashes — Pressure switch cycle lockout
- 7 red flashes — One hour lockout after ignition retries
- 8 red flashes — Lockout on recycles, flame dropouts
- 9 red flashes — Grounding, reversed polarity, or reversed transformer leads
- 10 red flashes — Gas valve energised with no call for heat
- 11 red flashes — Limit switch open more than five minutes — blower failure
- 12 red flashes — Open hot surface igniter
- Rapid red flashing — Twinning error or incorrect 24 volt phasing
- Rapid amber flashing — Low flame sense current
- Solid LED — Control fault detected
- Steady off — No power to the board, or control failure
- 2 red flashes — Pressure switch stuck closed, or an inducer error
- 4 red flashes — Open high limit switch
- 3 amber flashes — Second stage heat present with no first stage call
- 4 amber flashes — Cooling called with no fan call
- 2 amber flashes — Normal operation with a call for second stage heat
Reading the codes
- Reading a furnace fault code — How to find, count, and interpret the diagnostic light before looking anything up
- When to stop and call someone — The furnace conditions that are not a diagnosis problem
Goodman modulating display codes
- IF — Internal control fault
- Ft — Field test mode
- On — Normal operation
- F — Continuous fan
- A — Airflow display, followed by the CFM value
- H — Gas heat demand, followed by the demand percentage
- HI — High heat at 100 per cent demand
- LO — Low stage heat
- dF — Defrost demand
- P1 — Low stage compressor, heating mode
- P2 — High stage compressor, heating mode
- C1 — Low stage compressor, cooling mode
- C2 — High stage compressor, cooling mode
This site is a reference, not a substitute for a licensed HVAC technician. Gas appliances can leak carbon monoxide and cause fire. Anything involving gas lines, the heat exchanger, or the flame sensing circuit should be handled by a licensed professional. Pages are written with AI assistance from the sources listed on each page and checked against them before publishing.